Technical Information

BackPrint this page

Relative Performance Measurements
Curing Start/Working Time
Curing End Time/Minimum Loading Time
Performance Data Concrete
Consumption Chart

Relative Performance Measurements
  CF 800 CF 850 CF 900 CF 1000
Shrinkage
Behavior
approx. 1,0% approx. 1,0% approx. 0,6% 0%
Chemical
Resistance
+ + +++ ++++
Weight of Load
Possible
+ + +++ ++++
Underwater no no yes yes
Boring method
in solid stone
percussion percussion percussion diamond
Maximum
Drill Hole gap
up to 2 mm up to 2 mm up to 2 mm up to 4 mm
Wet and
Water-filled Holes
no no yes yes
Cure Time fast fast fast slow
Concrete yes yes yes yes
Solid Stone yes yes yes no
Hollow Brick yes yes yes no
Certification German and French
Certification for hollow bricks
no Fire Resistance
National and
European Approvals
EMPA
Styrene yes no no no
 

Curing Start/Working Time

Top
Temp CF 800 CF 850 CF 900 CF 1000
-5°C     90 min  
0°C     45 min 180 min
5°C 25 min 25 min 25 min 150 min
10°C 15 min 15 min 15 min 120 min
20°C 6 min 6 min 6 min 30 min
30°C 4 min 4 min 4 min 20 min
35°C 2 min 2 min 2 min 16 min
40°C       12 min
 

Curing End Time/Minimum Loading Time

Top
Temp CF 800 CF 850 CF 900 CF 1000
-5°C     360 min  
0°C     180 min 50 hours
5°C 120 min 120 min 120 min 37,5 hours
10°C 80 min 80 min 80 min 24 hours
20°C 45 min 45 min 45 min 10 hours
30°C 25 min 25 min 25 min 6 hours
35°C 20 min 20 min 20 min 5 hours
40°C       4 hours
 

Performance Data/Standard Application in Concrete

Top
Recommended Loads     M8 M10 M12 M16 M20
CF800
polyester-based
Concrete
≥ C 20/25
F rec [kN] 4,5 6,9 9,6 10,8 18,1
CF850
polyester-based
styrene free
Concrete
≥ C 20/25
F rec [kN] 4,7 7,1 10,0 11,2 18,8
CF900
vinylester-based
Concrete
≥ C 20/25
F rec [kN] 6,3 9,9 13,9 19,8 29,6
CF1000
pure epoxi
Concrete
≥ C 20/25
F rec [kN] 10,5 14,7 21,6 32,8 49,5
F rec [kN] = inc. safety factor
Values valid for zinc galvanized anchor rods 5.8 and stainless steel anchor rods A4-70.
 

Consumption Chart

Top
Numbers of Fixing in Concrete and Solid Material *
Anchor Diameter M 8 M 10 M 12 M 16 M 20 M 24 M 30
Borehole Diameter (mm) 10 12 14 18 24 28 35
Setting Depth (mm) 80 90 110 125 175 210 280
165 ml 41 25 15 8 3 2 1
280 ml 74 46 27 15 6 4 2
300 ml 80 49 30 16 6 4 2
345 ml 93 57 34 18 7 4 2
380 ml 103 63 38 20 8 5 2
385 ml 104 64 39 21 8 5 2
Number of Fixing in hollow brick *
Anchor Diameter M 8 M 10 M 12 M 16
Borehole Diameter (mm) 10 12 14 18
Approved Sleeve 13 x 100 15 x 100
Standard Sleeve 13 x 85 13 x 85 13 x 85 18 x 85
Standard 165 ml 12 12 12 6
Approved 165 ml 11 8
Standard 280 ml 23 23 23 12
Approved 280 ml 19 14
Standard 300 ml 24 24 24 13
Approved 300 ml 21 16
Standard 345 ml 28 28 28 15
Approved 345 ml 24 18
Standard 380 ml 31 31 31 16
Approved 380 ml 27 20
* These numbers are based on the best case scenario. This information can be used as a guide for planning purposes. Consumption chart values can vary based on specific usage and circumstances.
 

Top

Top
 
© 2008 Henkel AG & Co. KGaA | Terms of use | Imprint | Privacy Policy | Note for US Residents